Laminar Flow Hoods to provide an ultra-clean ISO 5 environment

Request More Information

For physics, precision mechanics, electronics, IT, and more.
Work in an ultra-clean environment.

Erlab’s laminar flow hoods provide optimal product protection, keeping your product safe from ambient air pollution. Each hood is fitted with  high-efficiency HEPA H14 (or ULPA U16) filters for optimal protection from particulate contamination and to provide an ISO class 5* working environment, according to the EN ISO 14644-1: 2015 standard. Additional protection from VOC contamination is also available with the combination of Carbon and HEPA filtration.

Additional value is added with SMART technology, an intuitive communication program which monitors the hood’s performance for ultimate product protection.

Request More Information

Powerful and innovative technology. ERLAB TECHNOLOGY Smart technology SMART technology informs users about their protection using light and sound. Light and sound pulses provide real time information indicating that: • Air face velocity is compromised: check sash, pre-filter or HEPA/ULPA filter • Fan failure has occurred 01 08 Particulate free workstation With more than 50 years of experience, Captair Flow Smart clean-air enclosures feature HEPA H14 (or ULPA U16) filters that provide optimum protection against external particulate contamination and are designed to provide an ISO 14644-1:2015, Class 5* work environment. 02 08 Electronic Anemometer The anemometer monitors a drop in pressure indicating that pre-filter or filter replacement is required. 03 08 Easy to install Erlab solutions may be moved from one location to another within the same laboratory according to your protection needs. They can be easily relocated without affecting the hood’s air balance. 04 08 Protect the environment Free of any ducted airflow system, Erlab solutions eliminate direct emissions of pollutants into the atmosphere and help protect the environment. They also avoid pollution generated by the energy needed to run the airflow systems of traditional ducted fume hoods. 05 08 Work surfaces Phenolic resin work surface - Work surface with built-in spill tray, made of phenolic resin, with an ergonomic arm rest to work confortably. - High chemical and mechanical resistance. - Ideal for precision weighing operations. Work surface in stainless steel 304 L High chemical and mechanical resistance. Rounded corners to facilitate cleaning operations. Built in spill tray. 06 08 Watch the video New Reverso front door Access to the medium or the low part with a simple move in total safety 07 08 LED lighting Compact fluorescent tube lights. One to three tubes, depending on the model. Dust and vapor-tight. Even, bright lighting of the work surface. 08 08 4 1 5 3 7 2 6 8

LAMINAR FLOW HOOD CLEAN AIR ENCLOSURES

Protection you can count on.

A range of advantages

Safety

Protected from all forms of pollution and every type of particle.

Learn More

Erlab filtration clean air enclosures are equipped with HEPA H14 (or ULPA U16) filters which provide optimal protection against external particulate contamination. They are designed to provide an ISO class 5* working environment according to the EN ISO 14644-1: 2015 standard.

Simplicity

Equipment that is easy to install and simple to use.

Learn More

Designed to fit any space, Erlab filtration clean air enclosures, with top mounted filtration columns, are installed quickly and simply.

They require no exhaust ducts and no connections other than to the power supply. After receiving the equipment, the laboratory is ready to operate in just a few hours.

Fitted with wheels, they can be moved very easily and allow laboratories to be reconfigured quickly as research programs evolve.

Their perfect ergonomic design makes them simple, practical, and comfortable to use.
When switching on, a single button centralizes operation of the ventilation, lighting, and on-board intelligence, allowing you to activate the power of SMART technology. 

Erlab filtration clean air enclosures are made using low-porosity materials which are easy to clean. Their integrated rounded-edge work surface is available in TRESPA® TopLab®PLUS or 304L stainless steel.

Their intuitive SMART safety system ensures that they are working correctly at all times. A single glance informs the user of the saturation status of the filters, which can be changed in just a few minutes.

A light bar at the top of the enclosure indicates the optimal level of protection afforded to the operation. Using different light and sound signals, the device communicates its operational status in real time via simple, clear, effective, and reliable indicators. 

Savings

Erlab filtration clean air enclosures help boost your laboratory’s productivity.

Learn More

With Erlab filtration clean air enclosures, you will realize savings on installation costs, maintenance costs, operating costs, and more. Their unique filtration system negates costly HVAC alterations and requires no additional assembly. Your operations are reliably ensured against pollution contamination, thus preventing project down time and loss of revenue.

Performance

Filter up to 99.99995% of particles.

Learn More

ULPA U16 filters guarantee 99.99995% filtration efficiency for particles larger than 0.1 μm. HEPA H14 filters guarantee 99.995% filtration efficiency for particles larger than 0.1 μm. An optional molecular filter can be added to provide additional protection from VOCs present in the laboratory air.

Connectivity

A high level of user protection.

Learn More

A light bar at the top of the device indicates the optimal level of safety for the operator. If any of the device’s operating parameters fall outside the range required for it to function correctly, the user is warned using one or more intuitive light and sound signals.

LOOKING FOR MORE INFORMATION?

Our team is here to help.

Request More Information

Resources

Product Brochure

Laminar flow clean air enclosure
Providing an ultra-clean, ISO 5 environment

Erlab Safety Program

Our commitment to your safety

Filtration Process Safety Guarantee

Erlab’s filtration process guarantees personal safety and laboratory success.

Erlab’s Flexible Payment Solutions

Powered by NEC Financial Services

What Makes Us Different

Recognizing the difference and superiority of Erlab’s filtration technology.

Laminar flow hood range

From length to width, height, depth, and power:
Erlab Laminar flow enclosures are available in 4 different models.

Model

Width (in)

Depth (in)

Height min (in)

Height max (in)

Power consumption

321

31⅞

25

43⅞

47⅞

55-35W

Download

391

39⅞

25

47⅝

51⅝

40-55W

Download

483

51⅛

37⅞

52¾

56½

95-90W

Download

714

71⅝

37⅞

52¾

56½

105-110W

Download

* Rooms with low levels of dust contamination

Laminar flow hood range

From length to width, height, depth, and power:
Erlab Laminar flow enclosures are available in 4 different models.

CaptairFlow 321

Dimensions
W  : 31⅞”
D  : 25″
H : 43⅞” (min.)
47⅞” (max)

55-35W

CaptairFlow 391

Dimensions
W : 39⅞”
D  : 25″
H : 47⅝” (min.)
51⅝” (max)

40-55W

CaptairFlow 483

Dimensions
W : 51⅛”
D  : 37⅞”
H : 52¾” (min.)
56½” (max)

95-90W

CaptairFlow 714

Dimensions
W : 71⅝”
D  : 37⅞”
H : 52¾” (min.)
56½” (max)

105-110W

* Rooms with low levels of dust contamination